Modification : 5'-BHQ-2
Catalog Reference Number
Category
Modification Code
5 Prime
3 Prime
Internal
Molecular Weight (mw)
Extinction Coeficient (ec)
Technical Info (pdf)
Absorbance MAX
Emission MAX
Absorbance EC
Catalog No | Scale | Price |
26-6728-50 | 50 nmol | $427.00 |
26-6728-02 | 200 nmol | $427.00 |
26-6728-01 | 1 umol | $481.00 |
26-6728-03 | 2 umol | $679.00 |
26-6728-06 | 5 umol | $2,164.50 |
26-6728-10 | 10 umol | $3,624.00 |
26-6728-15 | 15 umol | $4,531.00 |
Discounts are available for 5'-BHQ-2! |
Modification* Discount Price Structure |
1 site/order
|
List price
|
2 sites/order
|
10% discount
|
3 sites/order
|
20% discount
|
4 sites/order
|
30% discount
|
5-9 sites/order
|
50% discount
|
10+ sites/order
|
60% discount
|
*Exceptions apply
|
Black Hole Quencher-2 (BHQ-2) is classified as a dark quencher used as the 3'-quencher moiety in a variety of Fluorescence Resonance Energy Transfer (FRET) DNA detection probes. Such probes are primarily used in nucleic acid assays, but also find a place in nucleic acid structural studies (1). Examples include TaqMan probes (2), Scorpion primers (3), and Molecular Beacons (4).
BHQ-2 has an absorbance maximum of 579 nm, and an effective absorbance range of 550-650 nm. It is the preferred quencher for pairing with fluorescent dyes that emit in the yellow-orange part of the visible range (557-617 nm). The emission spectra of this set of dyes sufficiently overlaps the absorbance spectrum of BHQ-2 to allow the latter to quench the fluorescence of the former with a high degree of efficiency.
The advantages of using a dark quencher in a FRET probe are (a) low background fluorescence (and thus better signal-to-noise ratio), (b) higher dynamic range, (c) amenability to multiplex assays (due to a dark quencher having no secondary fluorescence), and (d) ease of synthesis of FRET probes with a dark quencher (due to dark quenchers being resistant to degradation during the oligo deprotection step) (5).
Click here for list of quenchers.
Click here for a list of fluorophores.
Quencher Spectral Data
|
Quencher
|
Absorption Max, nm
|
Quenching Range, nm
|
Dabcyl |
453 |
380-530 |
BHQ-0 |
495 |
430-520 |
BHQ1 |
534 |
480-580 |
BHQ2 |
579 |
550-650 |
BHQ3 |
672 |
620-730 |
BBQ-650 |
650 |
550-750 |
Click here for complete list of quenchers and details
|
**Black Hole Quencher License Agreement
Black Hole Quencher License Agreement.
"Black Hole Quencher®, BHQ®, CAL Fluor® and Quasar® are registered trademarks of
Biosearch Technologies, Inc., Petaluma, California.
The BHQ, CAL Fluor and Quasar dye technologies are protected by U.S. and world-wide patents either issued or in application. Compounds
incorporating these dyes are made and sold under agreement with Biosearch Technologies, Inc. for end-user's non-commercial research and development use only.
Their use in commercial applications is encouraged but requires a separate Commercial Use License granted by Biosearch Technologies, Inc."
|
References
1. Didenko, V.V. DNA Probes Using Fluorescence Resonance Energy Transfer (FRET): Designs and Applications. Biotechniques (2001), 31: 1106-1121.
2. Livak, K.J., Flood, S.J.A., Marmaro, J., Giusti, W., Deetz, K. Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization.PCR Methods Appl. (1995), 4: 1-6.
3. Thelwell, N., Millington, S., Solinas, A., Booth, J., Brown, T. Mode of action and application of Scorpion primers to mutation detection. Nucleic Acids Res. (2000), 28: 3752-3761.
4. Tyagi, S., Kramer, F.R. Molecular beacons: probes that fluoresce upon hybridization. Nat. Biotechnol. (1996), 14: 303-308.
5. Yeung, A.T., Holloway, B.P., Adams, P.S., Shipley, G.L. Evaluation of dual-labeled fluorescent DNA probe purity versus performance in real-time PCR. Biotechniques. (2004), 36: 266-270, 272, 274-275.
- BHQ-2 (Black Hole Quencher-2, 5')